Compatible case size |
Other |
Outline drawing |
73Wx35Hx180D |
Weight |
0.32 kg typ |
|
AC |
85-264V |
|
AC |
82% typical at AC 100V/85% typical at AC 200V |
|
99% typical at AC 100V/90% typical at AC 200V |
|
Worldwide |
|
UL60950-1, CSA60950-1 |
|
IEC61000-3-2 (Ed. 2.1) Class D compliant and EN61000-3-2 (A14) Class D compliant |
|
VCCI-B FCC-B CISPR22-B and EN55022-B compliant |
|
 |
|
Electrostatic discharge: EN61000-4-2 compliant Radiated, radio frequency electromagnetic fields: EN61000-4-3 compliant Fast transient burst: EN61000-4-4 compliant Lightning surge: EN61000-4-5 compliant Conductive radio frequency elctromagnetic fields: EN61000-4-6 compliant Power source frequency magnetic immunity: EN61000-4-8 compliant Voltage dips and fluctuation: EN61000-4-11 compliant |
|
268,000H |
|
-10 to 60 deg C, -10 to 70 deg C (with forced-air cooling) |
|
0.75mA max. |
|
Air-cooling without blower |
|
 |
|
Capacitor ground |
|
Three years after delivery; the defective unit shall be repaired or replaced at our cost if defects belong to us. |