80PLUS & ErP Directive Compliant. Low Power Consumption and High Efficiency SFX Power Supply ! |
|
80PLUS BRONZE approved SFX power supply Double-sided through hole PCB suitable for industrial use. High efficiency with synchronous rectification circuit Completely independent voltage-stabilizing circuit is mounted for all outputs. Min. load current is 0A for all outputs. Safety standard approved (IEC/UL/CSA/CCC) By building in the thermal-sensing variable speed fan, noise reduction can be realised. Heat-related issue for CPU can be settled with fan speed changeover switch. Medical standard IEC60601-1 3rd complied design |
|
Continuous
310W |
|
Peak
400W |
|
|
|
*Please use Metric Screw Threads, ("M3" screws) for PSU mounting.(Inch Screw Threads cannot be used.) |
Function :For description of function, click each icon
Output specification
Output connector : For description of function, click each icon
Standard, specifications: For standard and specifications, click each item.
Compatible case size |
SFX |
Outline drawing |
125Wx63.5Hx125D |
Weight |
1.0 kg typ |
Input Voltage |
AC |
85-264V |
Efficiency |
AC |
82%typ(AC100V)/85%typ(AC240V) |
Power factor |
96% min. (100 VAC), 90% min. (240 VAC) |
Input changeover system |
Worldwide |
Safety |
UL60950, CSA60950 (c-UL), CCC (S&E) approved EN60950, PSE (ministerial ordinance 2) compliant, CE Marking (LVD,EMC) |
High frequency current regulation |
IEC61000-3-2 Class D compliant |
EMI standard (Input feedback noise) |
VCCI-B, FCC-B, CISPR22-B, EN55022-B compliant |
CE marking |
LVD,EMC |
EMS immunity |
Electrostatic discharge: EN61000-4-2 compliant Radiate, radio frequency electromagnetic fields: EN61000-4-3 compliant Fast transient burst: EN61000-4-4 compliant Lightning surge: EN61000-4-5 compliant Conductive radio frequency electromagnetic fields: EN61000-4-6 compliant Power source frequency magnetic immunity: EN61000-4-8 compliant Voltage dips and fluctuation: EN61000-4-11 compliant |
MTBF |
70,000H min. |
Operating temperature |
0 to 60 deg.C* / 10 to 90% |
Leakage current |
0.2mA max. (100 VAC) / 0.4mA max. (200 VAC) / 0.5mA max. (240 VAC) |
Cooling systems |
Forced air cooling |
Insulation |
AC input - FG/DC output: 1500 VAC for 1 minute, |
Output ground connection |
Connected chassis (FG) |
Warranty |
3 years after delivery. If any faults belong to us, the defective unit shall be repaired or replaced at our cost. |