Compatible case size |
PS2 |
Outline drawing |
150Wx86Hx175D |
Weight |
2.2 kg typ |
Input Voltage |
AC |
85-264V |
DC |
24V(Dedicated battery package only) |
Efficiency |
AC |
80% typ(AC100V)/85% typ(AC240V) |
DC |
80% typ |
Power factor |
96% min. at AC 100V/90% min. at AC 200V
|
Input changeover system |
Worldwide |
AC, DC input |
|
Safety |
UL60950-1, CSA C22.2 No.60950-1,CCC, CE Marking (IEC62368-1) |
High frequency current regulation |
IEC61000-3-2 (Ed. 2.1) Class D and EN61000-3-2(A14)Class D compliant |
EMI standard (Input feedback noise) |
VCCI-A FCC-A and EN55022-A compliant |
CE marking |
Low Voltage Directive, EMC Directive |
EMS immunity |
Electrostatic discharge: EN61000-4-2 compliant Radiated,radio frequency electromagnetic fields: EN61000-4-3 compliant Fast transient burst: EN61000-4-4 compliant Lightning surge: EN61000-4-5 compliant Conductive radio frequency electromagnetic fields: EN61000-4-6 compliant Power source frequency magnetic immunity: EN61000-4-8 compliant Voltage dips/regulations: EN61000-4-11 compliant |
MTBF |
70,000H min |
Operating temperature |
0 to 60 deg C (load derating: 100% at 45 deg C, 70% at 60 deg C) |
Leakage current |
0.5mA max. at AC 100V, 1.0mA max. at AC 200V, 1.2mA max. at AC 240V
|
Cooling systems |
Forced air cooling |
Insulation |
AC input - FG/DC output: 1500 VAC for 1 minute,AC input - FG/DC output: 50M ohm min. |
Output ground connection |
Connected chassis (FG) |
Signal unit |
SU-RS (RS232C), SU-BU (buzzer), SU-US2 (USB) |
Warranty |
Three years after delivery; the defective unit shall be repaired or replaced at our cost if defects belong to us. |